7-42
Cn041.2 Turret mode return to zero function
【
5-5
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 --
0
~
1
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
002CH 2029H 2029H
--
--
O --
--
Setting Description:
Setting
Description
0 Not
Functioning
1
The driver execute turret return to zero function after
setting as 1; will automatically clear the setting to 0 after
completed.
Cn041.3 Current position return to zero
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
0 --
0
~
1
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
002CH 2029H 2029H
O
O
O O
O
Setting Description:
Setting
Description
0 Not
Functioning
1
The driver execute position return to zero function after
setting as 1; will automatically clear the setting to 0 after
completed.
Cn043 Analog monitoring output MON1 output proportion
JSDG2S-E does not
have this function
【
5-6-11
】
Initial Value
Unit
Setting Range
Effective
Cn029 Reset
100
%
-1000 ~ 1000
--
--
RS-485
CANopen
EtherCAT
Pi
Pe
Pt
S
T
002EH
202BH
202BH
O O O O O
Setting Description:Take 10V/1.5x rotational speed = 100% as example, if the analog monitoring output proportion is
changed to 10V/0.75x rotational speed, set the parameter as 200%
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......