background image

BB, CL & CC Series

1, 2 & 3 Door Horizontal Chillers

User Manual

MAN11015 R

ev

. 2

.1 Mar. 

2019

SKOPE Backbar, Counterline & Slimline

CL400

BB580

CL800

 

Summary of Contents for Backbar BB380i-2SL

Page 1: ...BB CL CC Series 1 2 3 Door Horizontal Chillers User Manual MAN11015 Rev 2 1 Mar 2019 SKOPE Backbar Counterline Slimline CL400 BB580 CL800 ...

Page 2: ... 535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service Support We know you will get years of satisfaction from your new S...

Page 3: ...g the Shelves 8 Loading Product 8 Remote Cabinet Installation 9 Electronic Controller 9 Pipe Locations 9 3 Operation Automatic Start Up 10 Refrigeration Unit 10 Cabinet Lighting 10 Electronic Controller 10 Electronic Controller 11 Controller Overview 12 Temperature Setpoint 12 Controller Alarms 13 4 Servicing Cleaning 14 Cabinet 14 Condenser Coil 14 Lighting 15 Cabinet Interior Lights 15 Troublesh...

Page 4: ...600i 3SL 3 Integral 3 4A CL800i 4SL 4 Integral 4 0A CL400i 2SW Swing doors 2 Integral 2 3A 1 C to 4 C up to 40 C ambient CL600i 3SW 3 Integral 3 2A CL800i 4SW 4 Integral 3 8A CL400r 2SL Sliding doors 2 Remote 0 5A 1 C to 4 C up to 32 C ambient CL600r 3SL 3 Remote 0 9A CL800r 4SL 4 Remote 1 3A CL400r 2SW Swing doors 2 Remote 0 3A CL600r 3SW 3 Remote 0 7A CL800r 4SW 4 Remote 1 0A Model Config Doors ...

Page 5: ... ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard Ensure all necessary safety precautions are observed during installation or removal of the refrigeration unit The appliance is not designed to be stable while in motion Use extr...

Page 6: ... cabinet is positioned on a level surface so the doors shut and seal correctly and to prevent the condensate tray from overflowing Ventilation For efficient operation of the chiller it is essential that adequate ventilation be provided around the front of the refrigeration unit Normal operating conditions should not exceed the operating temperature range see page 4 It is critical that the hot refr...

Page 7: ... can adjust the cabinet height up to 30mm To adjust leg height The adjustable castors screw into the castor mounting plates attached to the bottom of the cabinet The two lockable castors should be fitted to the front of the cabinet and the non locking castors fitted to the rear The adjustable castors can adjust the cabinet height up to 15mm To adjust castor height 1 Turn the black plastic foot at ...

Page 8: ...helf support strips are marked for easy location of shelf clips and can be lifted up and removed for cleaning purposes Loading Product The chiller should be left running for 30 minutes before loading with product When loading product Allow air space around all the product to ensure even cooling and efficient operation of the chiller Do not allow products to overhang the front of the shelf as this ...

Page 9: ...installation guidelines and specifications Electronic Controller When the cabinet is connected to the power supply the electronic controller will display the current cabinet temperature On the controller display the symbol will indicate the compressor output signal has been initiated and the symbol will indicate the evaporator fan is on Pipe Locations Refer to the images below remote chiller unit ...

Page 10: ... on and off depending on the cabinet temperature Cabinet Lighting The light switch located next to the electronic controller on the refrigeration unit front cover activates the cabinet interior lighting and can be switched on or off as required Electronic Controller When the cabinet is connected to the power supply the electronic controller will display the current cabinet temperature The compress...

Page 11: ...econds to initiate manual defrost To scroll settings down in program mode 5 Compressor ON when the compressor and condenser fan starts Flashes when activation of the compressor is temporarily delayed 6 Fan Shows when the fan is operational 7 Defrost ON when the defrost is activated Flashes when the activation of the defrost is temporarily delayed due to procedures in progress 8 Aux n a 9 Alarm Fla...

Page 12: ...ompressor is operating and the evaporator fan LED will normally come on within 2 minutes Temperature Setpoint The chiller temperature setpoint is factory set see table below and can be adjusted if necessary SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a time Factory setpoints To view and adjust the temperature setpoint M...

Page 13: ...eaters Flashing Product LOW temperature alarm auto reset Flashing Refrigeration system high temperature pre warning auto reset 1 Clean the condenser coil see page 14 2 Check refrigeration ventilation Ensure clear airpath in front of the cabinet 3 Ensure the cabinet is installed in a suitable environment 4 To reset the CHt alarm unplug the cabinet from the power supply for 1 minute then reconnect t...

Page 14: ...ay accumulate within the condenser that cannot be removed with a brush If this occurs contact SKOPE to arrange for a SKOPE authorised service agent to clean the condenser with compressed air The condenser coil is located inside the refrigeration unit compartment and is accessed by opening the unit front cover Disconnect the cabinet from the power supply before cleaning the condenser coil CAUTION D...

Page 15: ... Frosted LED tube Ø26 x 900mm 5500K Three door cabinet 24 Watt T8 Frosted LED tube Ø26 x 1500mm 5500K Four door cabinet Counterline Slimline 20 Watt T8 Frosted LED tube 2 Ø26 x 900mm 5500K Four door cabinet Backbar 24 Watt T8 Frosted LED tube Ø26 x 1500mm 5500K 1 Disconnect the cabinet from the power supply see page 14 2 Remove the top light diffuser by squeezing it until it is released from the h...

Page 16: ...od ventilation around the refrigeration unit Cabinet doors are opened excessively Keep door s open for minimum time 3 Product is too warm and spoiling Restricted cabinet airflow Ensure product is not blocking airflow slots Temperature setpoint is too warm Adjust setpoint see page 12 4 Warm cabinet temperatures and or compressor operating for long periods more than 1 hour Blocked condenser Clean co...

Page 17: ... the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applies any other trade mark to the product Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to ...