8-20
3. Control and monitor parameters
Parameters
Description
Address
Initial value
Unit
Pn401
Internal position command 1- lap
number
0701H
0
rev
Pn402
Internal position command 1- pulse
number
0702H/0703H
0
pulse
Pn403
Internal position command 1-
moving speed
0704H
0
rpm
Hn618
Communication control digital input
contact status
0512H
0
-
Un-01
Actual motor speed
0601H
-
rpm
Un-02
Actual motor torque
0602H
-
%
Un-30
Digital output contact status (Do)
061EH
-
-
Un-31
Digital input contact status (Di)
061FH
-
-
Un-32
Currently failed modbus
communication display
0620H
-
-
4. Control steps
●
Control SERVO ON: Hn618 = H0001
[DI-01(SON)=ON]
Send: 01 06 05 12 00 01 E8 C3 (the last two 2 codes are CRC)
●
Internal JOG, the speed is set by Sn201 (default 100rpm), control SPD1 ON: Hn618 = H0021
[DI-01(SON)=ON
、
DI-06(SPD1)=ON]
Send: 01 06 05 12 00 21 E9 1B (the last 2 codes are CRC)
The DI_Jog function can only be enabled under position mode (Cn01 = 2, 6, A)
DI_Jog_1
DI_Jog_2
0
0
No JOG function
1
0
JOG excitation_forward (speed Sn201)
0 1
JOG
excitation_reverse
(speed
Sn201)
1
1
JOG excitation_zero rotation
●
Control JOG speed: Sn201 = 200rpm
Send: 01 06 02 01 00 C8 D8 24 (the last 2 codes are CRC)
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......