5-35
5-3-7 Other Speed Control Functions
This Section explains other functions related to Speed Control.
Speed Reached Function
When Forward or Reverse Speed exceeds the speed set by
Cn007
(Speed Reached Determined
Value), Digital Output Contact
INS
operates; refer to following description:
Cn007 Speed Reached Determined Value
Initial Value
Unit
Setting Range
Effective
RS-485 Address
Rated rotational
speed* 1/3
rpm
0 ~ 1.5*Rated Speed
Effective after Set
0008H
Setting Description: When the Forward or Reverse Speed exceeds the speed set by Cn007 (Speed
Reached Determined Value), Digital Output Contact INS activates
Cn007
Speed Reached
Determined Value
Speed
Digital Output Contact INS State
ON
OFF