5-47
Pn301.1 Position Pulse Command Logic Selection
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
--
0 ~ 1
Power Re-set
0301H
Setting Description:
Setting
Description
0
Positive Logic
1
Negative Logic
Pn301.2 Drive inhibits Command Receiving Selection
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
--
0 ~ 1
Power Re-set
0301H
Setting Description:
Setting
Description
0
After the Drive Prohibition occurs, continue
recording the Position Command Input Quantity.
1
After the Drive Prohibition occurs, ignore Position
Command Input Quantity.
Pn301.3 Position Pulse Command Filter Width Selection
Initial Value
Unit
Setting Range
Effective
RS-485 Address
1
--
0 ~ 7
Power Re-set
0301H
Setting Description:
Setting
Description
Setting
Description
0 4500KHz 4 370KHz
1 2500KHz 5 190KHz
2 1200KHz 6 90KHz
3 750KHz 7 40KHz
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......