5-63
Setting Example:
(1) To reach 95% of Position Pulse Command Frequency Output in 30msec, then
10(ms)
95%)
-
ln(1
-
30(ms)
Pn313
(2) To reach 75% of Position Pulse Command Frequency Output in 30msec, then
22(ms)
75%)
-
ln(1
-
30(ms)
Pn313
(2) Internal Position Command S-type Smoothing Acceleration / Deceleration
The S-type Smoothing Command Generator provides smoothing processing of movement
commands, the generated speed and acceleration are continuous, and the jerkiness of acceleration is
also small, which can improve the acceleration / deceleration characteristics of the Motor, and also
more smoothing in the operations of the mechanical structure.
The S-type smooth command generator is suitable for the Control Mode when inputting the
Internal Position Command, when the Position Command is changed from the External Pulse Signal
Input, the input of Speed and Angular Acceleration are already continuous, so the S-type Smoother is
not used.
Pn322 Internal Position Command S-type Acceleration / Deceleration Smoothing
Constant (TSL)
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
0.4ms
0 ~ 5000
Effective after Set
031DH
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......