EtherCAT connection indicator (LINK/ACTIVITY)
Indicator
Status
Description
OFF Not
connected
Connection
not
established
ON Connected
Connection established but no data
transmission
Flickering
Network connected and data
transmitting
Data transmitting; the indicator flickers
with a frequency of 50ms ON, 50ms
OFF
EtherCAT operation indicator (RUN)
Indicator
Status
Description
OFF Initialization
Once power is connected, the EtherCAT
device will complete initialization but has not
yet started communication; however, the upper
device can still access the device's register.
Blinking
Pre-Operation
The upper controller can exchange data
through SDO
The indicator flickers with a frequency of
200ms ON, 200ms OFF.
Single Flash
Safe-Operation
The device can exchange data with the upper
device using SDO and TxPDO data packets.
The indicator flickers with a frequency of
200ms ON, 1000ms OFF, which means it
flashes once every 1s.
ON Operational
Able to transmit SDO, TxPDO and RxPDO
data packets
Flickering
SII parameters are loaded
when power is connected
Load SII parameter initialization; the indicator
flickers with a frequency of 50ms ON,50ms
OFF
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......