5-71
Other Return to Origin Setting Description
Return to Origin Speed Setting is as follows:
Pn318 Return to Origin First Stage High Speed
Initial Value
Unit
Setting Range
Effective
RS-485 Address
100
rpm
1 ~ rated rotational speed
--
0318H
Setting Description: Set the Moving Speed of Return to Origin First Stage High Speed
Pn319 Return to Origin Second Stage Low Speed
Initial Value
Unit
Setting Range
Effective
RS-485 Address
50
rpm
1 ~ rated rotational speed
--
0319H
Setting Description: Set the Moving Speed of Return to Origin Second Stage High Speed
The User can set the Return to Origin Offset Number of Revolutions / Number of Pulses, after
the Motor has found the Mechanical Origin in accordance with
Pn317
(Return to Origin Mode), it will
position in accordance with
Pn320
(
Return to Origin Offset Number of Rotations
)and
Pn321
(
Return to
Origin Offset Number of Pulses) as the New Mechanical Origin,
the setting is as follows:
Pn320 Return to Origin Offset Number of Revolutions
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0
rev
-30000 ~ 30000
Effective after Set
031AH
Setting Description: After the Motor has found the Mechanical Origin in accordance with
Pn317(Return to Origin Mode), it will position in accordance with Pn320
(Return to Origin Offset Number of Revolutions) and Pn321 (Return to Origin
Offset Number of Pulses) as the New Mechanical Origin
Pn321 Number of Pulse of Return to Origin Offset
Initial Value
Unit
Setting Range
Effective
RS-485 Address
0 pulse
-9999 ~ 9999: 2500ppr
-32767~32767: 15bit
-131071~131071: 17bit
-8388607~8388607: 23bit
Effective after Set
031BH/031CH
Setting Description: Return to Origin Offset Position =Pn320 (Number of Revolutions) x Number of
Pulses in One Revolution of EPn321(Number of Pulses)
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......