6-25
Pn338 Low Frequency Swinging Detection Level
Initial Value
Unit
Setting Range
Effective
RS-485 Address
50
0.1 %
1 ~ 1000
Effective after Set
032FH
Setting description: The detection level when executing automatic low frequency vibration
suppression (Pn336=1~3), this value setting method is used to set the percentage
of the positioning completion determined value (Pn307), adjusting the low
frequency swinging detection level (Pn338) can adjust the detection sensitivity,
and the lower the setting the easier for the noise to be determined incorrectly.
(2) Use PC-Link to run automatic mechanical resonance suppression enablement selection to look for
suppression frequency
1. Click “Tuning (T)” on the tool bar and select “Online Low Frequency Suppression (D)”
2. Set Pn336.0 (automatic mechanical suppression enablement selection)=1~3 and click the “write
in” key to enable automatic detection of low frequency vibration frequency.
3. When the low frequency vibration frequency is found, it will be displayed in low frequency
vibration frequency setting value column (Pn339, Pn341, Pn343). Low frequency suppression
parameter will also be set (Pn340, Pn342, Pn344) and return Pn336.0 to 0 automatically.
Summary of Contents for JSDG2S Series
Page 1: ......
Page 44: ...2 5 400V Class...
Page 303: ...5 178 2 3 1...
Page 693: ...10 7 10 2 Servo Drive Dimension 1 JSDG2S 10A 15A E 200V Class 2 JSDG2S 20A 30A E 200V Class...
Page 694: ...10 8 3 JSDG2S 10A 15A EL 200V Class 4 JSDG2S 20A 30A EL 200V Class...
Page 695: ...10 9 5 JSDG2S 10A 15A L 200V class 6 JSDG2S 20A 30A L 200V Class...
Page 700: ...10 14 Up to 130 Frame Series Up to 220 Frame Series...
Page 704: ...10 18 Up to 220 Frame Series Up to 130 Frame Series LL Without brake LL With brake IH Series...
Page 713: ...11 1 Chap 11 Appendix 11 1 Manual Revision History 11 2...
Page 718: ......