5-15
5-2-5 Internal Torque Limit Setting
In Torque Control, the user can set the Internal Torque Limit value based on the requirements,
setting is as follows:
Cn010
CCW Direction Torque Command Limit Value
Initial Value
Unit
Setting Range
Effective
RS-485 Address
200 ~ 300
(Note)
%
0 ~ 300
Effective after Set
000BH
(Note) Default and setting range of parameter Cn010/Cn011 vary by model. Please refer to “7-3-1
System parameters (Cn0
□□
)” for details.
Cn011
CW Direction Torque Command Limit Value
Initial Value
Unit
Setting Range
Effective
RS-485 Address
-300 ~ -200
Note)
%
-300 ~ 0
Effective after Set
000CH
Note) Default and setting range of parameter Cn010/Cn011 vary by model. Please refer to “7-3-1
System parameters (Cn0
□□
)” for details.