11-4
Parameterization
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
11.1 Status Indication
In the following, the frequency converter is referred to by the abbreviation
FC
.
Parameter
Setting value / description / note
Device
Supervisor
Parameter
record
P000
Status Indication
0.01 ... 9999
In the display of the standard control panel, the operating value selected in parameter
P001 is indicated
online
.
Depending on what is required, important information on the drive's operating state can be
read out.
P001
Selection of indicator value
0 ... 63
[ 0 ]
0 =
Actual frequency [Hz]
; this is the output frequency currently supplied by the
FC.
1 =
Speed [1/min]
; this is the actual speed calculated by the FC.
2 =
Setpoint frequency [Hz]
; this is the output frequency corresponding to the
applied setpoint value. It does not have to correspond to the current output
frequency.
3 =
Power [A]
; this is the current output power measured by the FC.
4 =
Torque current [A]
; this is the torque-forming output current of the FC.
5 =
Output voltage [V AC]
; this is current AC voltage supplied by the FC at the
output.
6 =
DC bus voltage [V DC]
; this is the internal DC voltage of the FC. This is
dependent, among other factors, on the value of the mains voltage
7 =
cos
ϕϕϕϕ
;
this is the currently calculated value of the power factor.
8 =
Apparent power [kVA]
; this is the current apparent power calculated by the FC.
9 =
Active power [kW]
; this is the current active power calculated by the FC.
10 =
Torque [%]
; this is the current torque calculated by the FC.
11 =
Field [%]
; this is the current field in the motor calculated by the FC.
12 =
Operating hours
; time in which mains voltage is applied at the FC.
13 =
Operating hours release;
time in which the FC is released.
14 =
Analog input 1 [%];
this is the current value applied at analog input 1 of the
FC.
15 =
Analog input 2 [%];
this is the current value applied at analog input 2 of the
FC.
16 =
reserved
17 =
reserved
18 =
reserved
19 =
Heat sink temperature (°C);
current temperature of the FC heat sink.
20 =
Motor capacity utilization [%];
average motor capacity utilization, based on
the known motor data (P201…P209).
21 =
Brake resistor capacity utilization [%];
average brake resistor capacity
utilization, based on the known resistor data (P556…P557).
22 =
… 63 reserved
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......