13-6
Technical Data
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
For the upper limits of the pulse deactivation dependent on pulse and
output frequency, consult the following tables.
In any case, the value that can be set in parameter P537 (10…200%) is
limited to the value indicated in the tables, depending on the pulse
frequency. Values below the limit can be set in any way.
Pulse
frequency
[kHz]
Output frequency [Hz]
4.5
3.0
2.0
1.5
1.0
0.5
0
3...8
200%
170%
150%
140%
130%
120%
110%
10
180%
153%
135%
126%
117%
108%
100%
12
160%
136%
120%
112%
104%
96%
95%
14
150%
127%
112%
105%
97%
90%
90%
16
140%
119%
105%
98%
91%
84%
85%
Fig. 13-5:
Overload capacity 230V devices
Pulse
frequency
[kHz]
Output frequency [Hz]
4.5
3.0
2.0
1.5
1.0
0.5
0
3...6
200%
170%
150%
140%
130%
120%
110%
8
165%
140%
123%
115%
107%
99%
90%
10
150%
127%
112%
105%
97%
90%
82%
12
130%
110%
97%
91%
84%
78%
71%
14
115%
97%
86%
80%
74%
69%
63%
16
100%
85%
75%
70%
65%
60%
55%
Fig. 13-6:
Overload capacity 400V devices
The percentages relate to the output current that the FC can supply for a
duration of 3.5°s.
230V devices
400V devices
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......