Rexroth IndraDrive FCS01.1
Parameterization
11-35
DOK-INDRV*--FCS01*****-IB01_EN-P
Parameter
Setting value / description / note
Device
Supervisor
Parameter record
P505
Absolute minimum
frequency
S
P
0.0 ... 10.0 Hz
[ 2.0 ]
Specifies the frequency value below that the FC cannot fall below. If the setpoint value
falls under the absolute minimum frequency, the FC will switch off or change to 0.0Hz.
At absolute minimum frequency, brake control (P434 or P441) and setpoint value delay
(P107) is executed. If the setting value "zero" is selected, the brake relay will not switch at
reversing.
With lifting gear controls, this value should be set to 2Hz as a minimum. The current
control of the FC works from 2Hz, and a connected motor can generate sufficient torque.
Note:
Output frequencies < 2Hz result in a current limitation. For more
details, see Chapter 13.2, Derating of Electrical Data.
P506
Automatic error
confirmation
S
0 ... 7
[ 0 ]
Alternative to the manual error confirmation, also automatic confirmation can be selected.
0 =
No automatic
error confirmation.
1…5 =
Number
of the permissible automatic error confirmations within one mains-
on-cycle. After mains switch-off and switch-on, the full number is available
once more.
6 =
Always,
an error confirmation is always confirmed automatically when the error
cause is no longer pending.
7 =
ENTER key,
confirmation is only possible with the Enter key or mains switch-off.
Confirmation is not executed by removing the release!
P507
PPO Type
1 ... 4
[ 1 ]
With the function modules FCC01.1F-xxx
P508
Profibus address
1 ... 126
[ 1 ]
With the function modules FCC01.1F-PB1 and –PB2
Also refer to Chapter 15, Master Communication - Field Busses and Protocols.
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......