Instructions with Regard to Specific Dangers
Protection Against Contact with Electrical Parts
Note:
This section only concerns devices and drive components with
voltages of more than 50 Volt.
Contact with parts conducting voltages above 50
Volts can cause
personal danger and electric shock. When operating electrical equipment,
it is unavoidable that some parts of the devices conduct dangerous
voltage.
DANGER
High electrical voltage! Danger to life, electric
shock and severe bodily injury!
⇒
Only those trained and qualified to work with or on
electrical equipment are permitted to operate,
maintain and repair this equipment.
⇒
Follow general construction and safety regulations
when working on electrical power installations.
⇒
Before switching on the device, the equipment
grounding conductor must have been non-
detachably connected to all electrical equipment in
accordance with the connection diagram.
⇒
Do not operate electrical equipment at any time,
even for brief measurements or tests, if the
equipment grounding conductor is not permanently
connected to the mounting points of the components
provided for this purpose.
⇒
Before working with electrical parts with voltage
potentials higher than 50 V, the device must be
disconnected from the mains voltage or power
supply unit. Provide a safeguard to prevent
reconnection.
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......