11-22
Parameterization
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
Parameter
Setting value / description / note
Device
Supervisor
Parameter
record
0 ... 400.0 %ms
[ 1.0 ]
Only effective if the function actual frequency PID has been selected.
In case of a deviation, the D quota of the PID controller will define the frequency
modification multiplied by time.
P416
Ramp PID controller
S
P
0.00 ... 99.99s
[ 2.00 ]
Only effective if the function actual frequency PID has been selected.
Ramp for the setpoint PID
P417
Offset analog output
S
P
-10.0 ... 10.0 V
[ 0.0 ]
In the analog output function, an offset can be set to simplify processing of the analog
signal in several devices.
if the analog output is programmed with a digital function, the difference between
activation point and deactivation point (hysteresis) can be set in this parameter.