8-14
Installation
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
X5, Connection of Braking Resistor (+B, -B)
The terB/-B are provided for connection of a suitable braking
resistor. For the connection, select a twisted and shielded link which is as
short as possible (
maximum permissible length 2 x 5 m).
Fig. 8-16:
Connection of braking resistor
Note:
The braking resistor heats up during operation.
•
Place the braking resistor at a sufficient distance from
heat-sensitive components.
•
Provide sufficient ventilation for the brake resistor.
•
The application of the FLR01 is not UL/cUL-certified.
WARNING
Damage to the device due to incorrect
connection!
⇒
Connect the braking resistor only bB and -
B. Make sure specifically to avoid short-circuit
against ground.