9-10
Indications and Operation of the Function Modules
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
Initial Commissioning
When the frequency converter is switched on for the first time with the
plugged-on comfort control panel, the menu language (German, English)
is queried. Then, the comfort control panel automatically does a "bus
scan" to identify the connected frequency converter. When the frequency
converter has been identified, its type, current operating state and current
status is indicated.
After release of the frequency converter, the display changes to the three
standard operating values (frequency, voltage, power). The indicated
current operating values can be selected from a list.
Note:
The factory setting for the digital frequency command value is
0Hz. To check whether the drive is working, enter a frequency
command value via the
key, or a jog frequency (P113).
Settings may only be made by qualified personnel under strict
observation of the safety instructions and warnings.
ATTENTION!:
The drive will possibly start moving immediately
after the START key
has been pressed!