DOK-INDRV*--FCS01*****-IB01_EN-P
Mounting
For
mounting
the FCC01 function module, follow the steps listed below:
•
Switch the mains voltage off, observe the waiting period.
•
Push the control terminal cover downwards or take it off.
•
Remove the blind cover by unlocking it at the lower edge and twist it
off in an upwards movement. Possibly, the fixing screw next to the bolt
must be removed.
•
Hook the FCC01 function module on at the upper edge and press
lightly to snap it home. Check the connector bar for perfect contact
and fix with the screw (included) if necessary.
•
Re-close the control terminal cover.
Fig. 9-2:
Sample for mounting the FCC01 function module
WARNING
⇒
The modules may only be inserted or removed when
the system is de-energized. The slots can only be
used for the intended modules. It is not possible to
mount the FCC01 function modules
away from the
frequency converters,
they must be plugged on to
X43
directly at the frequency converter.