15-20
Control Communication - Field Busses and Protocols
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
To switch the converter into
Ready for activation
status, the following
telegram must be transmitted:
9
10
11
12
CTW
CTW
SP1
SP1
04
7E
00
00
When the converter has switched to
Ready for activation
state, it will
transmit the following response telegram:
9
10
11
12
STW
STW
AV1
AV1
0B
31
00
00
Note:
The control telegram must be transmitted cyclically as it
cannot be guaranteed that the converter goes to the desired
state within the response time of a telegram.
Enable with 50% setpoint value
A frequency converter which is in "Ready for activation" state is to be
enabled with 50% setpoint value in clockwise rotation. The control has
received a last response telegram as follows.
Procedure:
•
Check status word (STW 0B 31)
•
Generate control word (STW 04 7F)
•
Check response telegram (STW 0F 37)
Details:
Precondition (status word of the converter)
9
10
11
12
STW
STW
AV1
AV1
0B
31
00
00
The following telegram must be sent to the converter:
9
10
11
12
CTW
CTW
SP1
SP1
04
7F
20
00
The converter accelerates the motor at the ramp. When the converter has
reached 50% setpoint value, it will respond by transmitting the following
telegram:
9
10
11
12
STW
STW
AV1
AV1
0F
37
20
00
Note:
In bit 10 of the response telegram, the status of MFR 1 is
signaled. Depending on the programmed function and state,
the status word may change.
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......