![REXROTH IndraDrive Fc FCS01 Operating Instructions Manual Download Page 176](http://html.mh-extra.com/html/rexroth/indradrive-fc-fcs01/indradrive-fc-fcs01_operating-instructions-manual_1449570176.webp)
15-12
Control Communication - Field Busses and Protocols
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
Bit
Valu
e
Significance
Notes
1
Comparison value
MFR 1 reached
Programmed function of the MFR 1 met,
or
actual value > programmed comparison
value
0
11
1
Clockwise
rotation
The motor defaults to clockwise type
revolving field
0
12
1
Counterclockwise
rotation
The motor defaults to counterclockwise
type revolving field
0
reserved
13
1
reserved
14
0/1
Current active
parameter record
0
15
0/1
Current active
parameter record
1
00 parameter record 1
01 parameter record 2
10 parameter record 3
11 parameter record 4
Fig. 15-15: Bit significance STW - status word