11-52
Parameterization
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
11.7 Pertinent Parameters, User Settings
(P)
⇒
dependent upon parameter record, these parameters can be
variously set in 4 parameter records.
Setting after commissioning
Parameter
no.
Designation
Factory
setting
Super
visor
P 1
P 2
P 3
P 4
STATUS INDICATIONS
P000
Status Indication
P001
Selection of indicator value
0
P002
Display factor
1.00
S
P003
Supervisor code
1
BASIC PARAMETER
P100
Parameter record
0
S
P101
Param. record copied
0
S
P102
(P) run-up time [s]
2.0
P103
(P) braking time [s]
2.0
P104
(P) Minimum frequency [Hz]
0.0
P105
(P) Maximum frequency [Hz]
50.0
P106
(P) Ramp rounding [%]
0
S
P107
(P) Brake application time [s]
0.00
P108
(P) Switch-off mode
1
S
P109
(P) DC current - brake [%]
100
S
P110
(P) Time DC brake on [%]
2.0
S
P111
(P) P factor torque limit [%]
100
S
P112
(P) Torque current limit [%]
401 (off)
S
P113
(P) Jog frequency [Hz]
0.0
S
P114
(P) Brake application time [s]
0.00
S
MOTOR DATA / CHARACTERISTIC PARAMETER
P200
(P) Motor list
0
P201
(P) Nominal motor frequency
[Hz]
50.0 *
S
P202
(P) Nominal motor speed [rpm]
1385 *
S
P203
(P) Nominal motor current [A]
4.8 *
S
P204
(P) Nominal motor voltage [V]
230 *
S
P205
(P) Nominal motor power [kW]
1.10 *
P206
(P) Motor cos phi
0.78 *
S
P207
(P) Motor connection
[star=0/delta=1]
1 *
S
P208
(P) Stator resistance [
Ω
]
6.28*
S
P209
(P) No-load current [A]
3.0 *
S
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......