Rexroth IndraDrive FCS01.1
Parameterization
11-25
DOK-INDRV*--FCS01*****-IB01_EN-P
Parameter
Setting value / description / note
Device
Supervisor
Parameter
record
P422
Function digital input 3
0 ... 62
[ 8 ]
Parameter record switch bit 0
as factory setting
Various functions may be programmed. Please refer to the following table.
P423
Function digital input 4
0 ... 62
[ 4 ]
Fixed frequency 1
(P429) as factory setting
Various functions may be programmed. Please refer to the following table.
P424
Function digital input 5
0 ... 62
[ 0 ]
No function
as factory setting
Various functions may be programmed. Please refer to the following table.