7-2
Mounting
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
recommend to mount an "obstacle" (e.g. a cable duct) between the
frequency converters which will interrupt the direct air flow (rising warm
air).
Efficiency:
On installation in a control cabinet, ensure sufficient
ventilation. During operation, lost heat in the amount of approx. 5%
(depending on unit size and equipment) of the nominal power of the
frequency converter will occur.
7.2
Dimensions of the FCS01 Frequency Converter
Housing dimensions [mm]
Wall mounting bracket mm]
Device type
Size
L
W
D
L1, approx
∅
∅
∅
∅
FCS01.1E-W0003-A-02
FCS01.1E-W0005-A-02
FCS01.1E-W0006-A-02
FCS01.1E-W0008-A-02
FCS01.1E-W0003-A-04
FCS01.1E-W0005-A-04
A
186
74
153
220
5.5
FCS01.1E-W0011-A-02
FCS01.1E-W0015-A-02
FCS01.1E-W0019-A-02
FCS01.1E-W0006-A-04
FCS01.1E-W0011-A-04
B
226
73
153
260
5.5
FCS01.1E-W0015-A-04
FCS01.1E-W0019-A-04
C
241
98
178
275
5.5
FCS01.1E-W0025-A-04
FCS01.1E-W0032-A-04
D
286
98
178
320
5.5
B
L
T
Fig. 7-2:
Dimensions of the IndraDrive Fc frequency converters