SECTION 6
Communication with External Devices
JUDGE (or J)
Function......Obtains the most recent judgment result.
JUDGE(or J) <Output>
•
Specify an output between 0 and 8.
When the output is set to 0 to 7
: Judgment result
When the output is set to 8
: 0, Judgment result
1, Judgment result
⋅
⋅
OK
Other errors
: ER
LD-OFF
: LDOFF
Measurement not possible
: RST
•
The following judgment results will be output from the Controller.
The last value measured is output if hold output is specified.
Values according to the hold setting are output at logging output.
Example:
Output #
Meaning
0
OUT0
1
OUT1
2
OUT2
3
OUT3
4
OUT4
5
OUT5
6
OUT6
7
OUT7
8
OUT0 to 7
Output #
Meaning
0
PASS
1
HIGH
2
LOW
3
ERROR
Input
Delimiter
Output
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
J 1
The judgment result for OUT1 is obtained.
0
The judgment result is within the judgment value range (PASS).
Input
Delimiter
Output
Delimiter