SECTION 6
Communication with External Devices
Example:
PROFILE or P
Function......Obtains profile data (distribution of height measurements at 1024 points).
(Can only be performed when the measurement mode is [Continuous].)
PROFILE or P
The output result is the same as for the CAPTURE command. Refer to the explanation
of the CAPTURE command.
p.209
Assuming the measurement period is 1000 ms, one sampling period is 9.96 ms, and the total
number of outputs is 2.
TREND 0 2
Obtains the measurement result of OUT0.
50
Number of measurement values
253.531112
497.575653
⋅
⋅
⋅
369.978239
OK
Input
Delimiter
Output
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
50 measurement values (obtained as 50 = 1000 ms
÷
9.96 ms
÷
2) are output.