![background image](http://html.mh-extra.com/html/omron/z550/z550_operation-manual_1633335072.webp)
70
S
E
CT
ION 3
Se
tting
Me
asu
reme
nt Ite
m
s
Z550
Operation Manual
SECTION 3
Setting Measurement Conditions (Expert Menu)
Setting Measurement Items
Up to eight measurement items can be set for each scene.
The Controller provides 12 measurement items, each of which can be assigned to outputs OUT0 to
OUT7.In other words, it is possible to perform up to eight measurements simultaneously.
[Height] is set in OUT0 as the default setting at shipment.
Measurement item
Meaning
Explanatory
diagram
Reference
Height
The height is measured within the specified region.
p.72
Step: 2 pts
Two target measurement lines are specified.
After taking the measurement point on the 1st line as
the reference, the distance from the measurement
point on the 2nd line is measured.
p.74
Step: 3 pts
Three target measurement lines are specified.
After taking the average of the measurement points
on two of the lines specified above, the difference
from the measurement point on the 3rd line is
measured.
p.75
Edge position
The specified edge position is measured.
p.78
Width
The difference between the specified two edge
positions is measured.
p.81
Edge center
The center is measured based on the specified two
edge positions.
p.84
Peak/bottom
The peak or bottom point of the height within the
specified measurement target line is measured.
p.85
operation.book Page 70 Monday, June 6, 2005 10:19 AM