SECTION 6
Communication with External Devices
Timing Charts
Timing Chart 1
Measurements are made at a fixed interval when the Controller is in the Measurement mode,
and then the results are output.Hold measurement is not performed.
*1 Profile data for which arithmetic processing has been completed when the PROFILE command is
received is transmitted.
Measurement mode
Hold&Logging
Free
Hold output
Logging output
External trigger
Self trigger
Continuous
measurement
Timing Chart 1
p.222
Timing Chart 2
p.223
Timing Chart 3
p.224
Timing Chart 4
p.225
Trigger measurement
(External)
Timing Chart 5
p.226
Timing Chart 6
p.227
Timing Chart 7
p.228
Timing Chart 8
p.229
Trigger measurement
(RS-232C)
Timing Chart 9
p.230
Timing Chart 10
p.231
Timing Chart 11
p.232
Timing Chart 12
p.233
Measurement mode
Hold&Logging
Continuous measurement
Free
Image acquisition
Measurement time
Calculation
processing
Terminal block output
Analog output
PROFILE command
(received by Controller)
PROFILE data
(sent by Controller)
PROFILE command
RUN output OFF
ON
BUSY output OFF
ON
PROFILE data( *1)