![background image](http://html.mh-extra.com/html/omron/z550/z550_operation-manual_1633335163.webp)
161
Z550
Operation Manual
S
E
CT
IO
N 4
Te
stin
g M
eas
ur
em
ent Pe
rfor
ma
nce
(Tes
t)
SECTION 4
Other Functions
The test measurement screen appears.
4.
Position the workpiece to be tested and press the
ENT Key.
A menu for selecting test methods appears.
5.
Set [Test mode] to [# times].
6.
Make the required setting for [# of samples] and
select [End].
The screen display returns to
4
.
7.
Display the output whose measurement value you want to check.
Up/Down key: Switches between outputs.
8.
Press the TRIG Key.
The test measurements are performed for the number of
times set and the measurement results are displayed.
Press the Left/Right key in order to switch between
displays.
9.
To continue testing, repeat the operations of
7.
and
8
.
10.
To stop the test measurements, press the ESC Key.
The display returns to the Tools mode screen.
OUT0
-----------mm [STOP]
MAX-MIN
No.
1
2
3
4
5
AVE
NUM
Scn 0
䂯
Tools
䂯
OUT0
-0010.53150mm [STOP]
MAX-MIN
No.
1
2
3
4
5
AVE
NUM
Scn 0
䂯
Tools
䂯
Test mode
䋺
# times
䂯
# of samples: [
䇭
100]
End
When measurement starts, the display
changes from [STOP] to [RUN].
During measurement, [RUN] flashes.
-001.81313 mm [
RUN
]
MAX-MIN
+0000.00367
+0000.00305
AVE
-0001.82836
-0004.82600
NUM
100
100
OUT0
No.
1
2
3
4
5
Scn 0
䂯
Tools
䂯
operation.book Page 161 Monday, June 6, 2005 10:19 AM