SECTION 3
Setting Measurement Conditions (Expert Menu)
When Selecting [Multi]
Position a reference workpiece and perform the following operations.
The sensitivity level is automatically set for each line based on the brightness of the reflection
from the reference workpiece.
1.
Select [Image/Sensitivity].
The selections for sensitivity adjustment appear.
2.
Select [Multi].
The multiple sensitivity setting screen appears.
3.
Check that the workpiece is positioned within the
measurement range and press the ENT Key.
The sensitivity level will be registered and the screen display returns to
1
.
After the settings have been completed, fine adjustment can be made under [Details].
p.54
Image
Detect set
Meas set
Extra set
Meas
mode
Scn 0
䂯 䇭
Set
䂯
Meas method
Region
Sensitivity
Details
Auto
Fixed
Multi
Scn 0
䂯
Set
䂯