225
Z550
Operation Manual
S
E
CT
IO
N 6
Tim
ing Ch
arts
SECTION 6
Communication with External Devices
Timing Chart 4
Measurement values are accumulated and output according to the logging settings during a
continuous measurement. When the hold conditions are specified, the corresponding values are
held, accumulated, and then output.
Assuming the sampling interval is set to three samples
*1 ALL-PASS and ERROR outputs are always output at the timing when "no hold" is set.
*2 The GATE output does not function at logging.
*3 Profile data for which arithmetic processing has been completed when the PROFILE command is
received is transmitted.
Measurement mode
Hold&Logging
Continuous measurement
Logging
Image acquisition
Measurement time
Calculation processing
Terminal block output
Analog output
(OUT for which hold is set)
PROFILE command
(received by Controller)
PROFILE data
(sent by Controller)
Accumulated data
(OUT for which hold is set)
Accumulated data
(OUT for which
no hold is set)
Terminal block output (*1)
Analog output
(OUT for which no hold is set)
PROFILE command
GATE output
(*2)
OFF
ON
PROFILE data (*3)
RUN output OFF
ON
BUSY output OFF
ON
Accumulate values according to the hold setting.
Accumulate data once every three measurements
Output value according to the hold setting
operation.book Page 225 Monday, June 6, 2005 10:19 AM