![background image](http://html.mh-extra.com/html/omron/z550/z550_operation-manual_1633335109.webp)
107
Z550
Operation Manual
S
E
CT
ION 3
Se
tting
Span
and
O
ffset
SECTION 3
Setting Measurement Conditions (Expert Menu)
Setting Span and Offset
The span and offset can be set in order to fine-tune the measurement values. They can be specified for
each output.
They have been set automatically after executing the calibration; make modification as necessary.
1.
Select [Meas set].
Item
Meaning
Span
Gain attribute of the sensor characteristic. (0.20000 to 4.0000, set to 1.000000 by default setting)
Offset
It is possible to add/subtract a fixed value to/from the measurement value.
(-999.999999 to 999.999999, set to 0.000000 by default setting)
Measurement value
䋨
mm
䋩
Displacement
of workpiece
0.2
4.0
Measurement value
(mm)
Displacement
of workpiece
Scn 0
䂯䇭
Set
䂯
Image
Detect set
Meas set
Extra set
Meas mode
Output