Communication with External Devices
Setting the Profile Output Method
Specify the communication method when profile data is output according to the following
procedure.
1.
Enter the System mode and select [Profile].
p.174
The setting screen appears.
2.
Select a value for each item.
3.
Select [End].
The setting will be registered and the screen display returns to
1
.
Scn 0
ٕ
System
ٕ
Comm
Profile
Environment
Initialize
Version
Out data
Start data
End data
Data interval
Data size
Data unit
End
Scn 0
䂯
System
䂯
Xmodem
[ 0]
[1023]
[ 1]
3Byte
mm
:
:
:
:
:
:
Item
Option/Setting range
Meaning
Out data
Text
The profile data is transmitted in text format.The post-
processing will be simple, but the communication time
becomes longer as the amount of data is large.
XMODEM
(Default setting)
The profile data is converted to binary format and then
transmitted. The number of data items is smaller than
for the text format and the communication time is
shorter, but the following precautions must be taken.
•
It is necessary to convert the binary format data in
order to perform post-processing.
•
Software supporting XMODEM communication is
required.
Communication flow p.212