167
Z550
Operation Manual
S
E
CT
IO
N 4
Bac
k
in
g up
Settin
g
Data
SECTION 4
Other Functions
2.
Specify the Controller communication settings.
The default communications settings at the shipment are as shown in the following table.Use the default
settings under normal circumstances.
Setting communication specifications p.196
3.
Start the Hyper Terminal program on the PC and specify the communication settings as follows.
The same communication settings must be used for both the Controller and the modem on the PC side.
* The flow control is not performed because the XMODEM protocol is used for the communication.
4.
Once the preparations have been completed on the
PC, enter the Tools mode.
Item
Setting value
Baud rate
38400 (bps)
Data length
8 (bit)
Parity
None
Stop bits
1 (bit)
Delimiter
CR
Flow control
None*
Item
Setting value
Bits per second (B) 38400 (bps)
Data bits (D)
8 (bit)
Parity
None
Stop bits
1 (bit)
Flow control
None*
Scn 0
䂯
Run
䂯
Set
Run
Tools
System
Save
operation.book Page 167 Monday, June 6, 2005 10:19 AM