Operation Manual
SECTION 6
Communication with External Devices
Perform the following procedure in order to set and fix the optimum sensitivity for the workpiece
to be measured.
Example:
SENSM
Function 1......Sets the sensitivity adjustment method to [Multi] and obtains the optimum
sensitivity for the workpiece.
SENSM <Priority item>
Specify either 0 or 1 for the priority item.
Command executed correctly
: Sensitivity lower limit, sensitivity upper limit
Command not executed correctly : ER
Priority item
Meaning
0
Priority on dynamic range
1
Priority on sampling period (default selection when
setting is omitted)
SENS
17
The optimum sensitivity is 17.
SENS 15 19 170
OK
The sensitivity level is automatically adjusted in the range between 15 and 19 with a
target light reception level of 170.
Input
Delimiter
Output
Delimiter
Input
Delimiter
Output
Delimiter
Input
Delimiter
Output
Delimiter
Delimiter