![background image](http://html.mh-extra.com/html/omron/z550/z550_operation-manual_1633335206.webp)
204
S
E
CT
IO
N 6
RS-2
32
C
Z550
Operation Manual
SECTION 6
Communication with External Devices
SCENE
Function 1......Obtains the scene being displayed.
SCENE
Command executed correctly
: Scene
Command not executed correctly
: ER
Example:
Function 2......Switches the scene to be measured.
SCENE <Scene >
Specify a scene between 0 and 15.
Command executed correctly
: OK
Command not executed correctly
: ER
Example:
It is not possible to switch scenes using RS-232C commands if [Environment/Scene] in the System
mode is set to [Terminals].(ER is output.)
Input
Delimiter
Output
Delimiter
Delimiter
SCENE
:4
Scene 4 is being displayed.
Input
Delimiter
Output
Delimiter
Input
Delimiter
Output
Delimiter
Delimiter
SCENE 2
OK
In this example, the scene is switched to scene 2.
Input
Delimiter
Output
Delimiter
operation.book Page 204 Monday, June 6, 2005 10:19 AM