SECTION 6
Communication with External Devices
Timing Chart 11
Hold measurement is started when the result obtained by triggering the CAPTURE command of
RS-232C matches with the trigger conditions.
Assuming the measurement duration is specified to twice the measurement time (*1)
*1 Specify the measurement duration to 100 ms when the measurement time is 100 ms in order to set it
to twice the measurement time.
*2 ALL-PASS and ERROR outputs are always output at the timing when "hold" is set.
Measurement mode
Hold&Logging
Trigger measurement
(RS-232C)
Hold (Self)
Image acquisition
Calculation
processing
Terminal block output (*2)
Analog output
(OUT for which hold is set)
PROFILE data
(sent by Controller)
Terminal block output
Analog output
(OUT for which no hold is set)
GATE output
OFF
ON
GATE
ON delay
RUN output OFF
ON
BUSY output OFF
ON
CAPTURE
command
(received by Controller)
Output value according to the hold setting
GATE
ON time
Measurement time
This result matches with the trigger condition.