SECTION 6
Communication with External Devices
Item
Option
Meaning
Format
Command
(Default setting)
Measurement data is output only when a data acquisition command
(e.g., MEASURE or JUDGE) is input from an external device.
Trigger OFF
When hold output or logging output is used, the measurement data is
output after the profile data is output. It is not necessary to enter a
data acquisition command (e.g., MEASURE or JUDGE).
Data
Measurement
(Default setting)
Measurement values are output to RS-232C.The output method is the
same as for the MEASURE command.
Result
Judgment results (HIGH/PASS/LOW/ERROR) are output to RS-
232C.The output method is the same as for the JUDGE command.
Result
The judgment result is output first, followed by the measurement
value.
Output #
OUT0 to OUT7
(Set to OUT0 by
default setting)
Select the output (OUT0 to OUT7) whose data is to be output.
When [Consecutive] is selected, the data of OUT0 through OUT7 will
be output continuously in series.
Consecutive