231
Z550
Operation Manual
S
E
CT
IO
N 6
Tim
ing Ch
arts
SECTION 6
Communication with External Devices
Timing Chart 10
After the TRG signal of the terminal block is input, hold measurement is performed based on the
measurement results obtained by the CAPTURE command of the RS-232C.
Assuming the measurement duration is specified to three times the measurement time (*1)
*1 Specify the measurement duration to 200 ms when the measurement time is 100 ms in order to set it
to three times the measurement time.
*2 ALL-PASS and ERROR outputs are always output at the timing when "hold" is set.
Measurement mode
Hold&Logging
Trigger measurement
(RS-232C)
Hold (External)
Terminal block output (*2)
Analog output
(OUT for which hold is set)
PROFILE data
(sent by Controller)
Terminal block output
Analog output
(OUT for which no hold is set)
Measurement time
(internal signal)
OFF
ON
TRG
of terminal block
OFF
ON
GATE output OFF
ON
RUN output OFF
ON
BUSY output OFF
ON
Measurement time
Calculation
processing
Image acquisition
CAPTURE
command
(received by Controller)
GATE
ON time
GATE
ON delay
Output value according to the hold setting
operation.book Page 231 Monday, June 6, 2005 10:19 AM