SECTION 6
Communication with External Devices
Analog Output
Measurement results can be output as current in the range 4 to 20 mA and as voltage in the range -5 to
5 V.
Only one of the outputs from OUT0 to 7 can be output.
Using the menus, specify the output number whose measurement result you want to output and the
scaling value.
Output during reset input
During restart (approx. 20 seconds after the power supply is turned on), 0 V and 12 mA are output to the
analog output terminals.Make sure that these outputs are not treated as actual signals by external devices.
1.
Enter the Set mode and select [Output].
Scn 0
䂯䇭
Set
䂯
Output
4mA(-5V)
20mA(+5V)
䋺
䋺
䋺
OUT0
䂯
[ -20.000000]mm
[ 20.000000]mm
End
Set the measurement value corresponding to the upper limit of the
analog output (20 mA/+5 V)
䋨
-999.999999 to 999.999999 mm
䋩
.
The default setting at shipment varies depending on the sensor
model that is connected.
Select the desired output (OUT0 to OUT7).
Set the measurement value corresponding to "4 mA/-5 V" in the
analog output
䋨
-999.999999 to 999.999999 mm
䋩
.
The default setting at shipment varies depending on the sensor
model that is connected.
20mA
(+5V)
4mA
(-5V)
Measurement value
Measurement
upper limit
Measurement
lower limit
Analog output