SECTION 2
Basic Operations
Step
3
Setting the Measurement Region
The measurements obtained may not be stable due to influence from the background etc. with the
default measurement region set at the shipment. In this case, set the measurement region so that only
the measurement target is included.
If there is a possibility that the position of the workpiece may be shifted, determine the size of the region
taking the possible range of movement into consideration as well.
1.
Position the workpiece.
2.
Press the ENT Key.
The screen for specifying the region appears.
3.
Adjust the region so to surround only the
measurement target area.
Up/Down/Left/Right key: Moves the cursor.
(Press these keys together with the SHIFT Key to move
the cursor quickly.)
ENT Key: Selects the setting.
The measurement region is registered.
Measurement image displayed.
Check workpiece position.
ENT:Next ESC:Back
Profile
Sen0's measurement region
Strt+000.1836mm Stp-000.1596mm
Strt 200lines Stp 723lines
ENT:Next ESC:Back
Proceed to
Step
4
.