113
Z550
Operation Manual
S
E
CT
ION 3
Se
lec
ting
Incl
inati
on Com
p
en
sati
on Error Ha
nding
SECTION 3
Setting Measurement Conditions (Expert Menu)
Selecting Inclination Compensation Error Handing
This function is only valid when Inclination compensation has been specified.
Select whether or not to treat the measurement result as an error when it is not possible to measure the
reference height of a region.
[Slant error] cannot be specified for [Define].Errors are handled according to the [Slant error] settings
specified for the other outputs set in the defining equation.
1.
Select [Meas set].
The selections for output appear.
2.
Move the cursor to the output to be set and press
the ENT Key.
Option
Measurement
of reference
height
Measurement processing
Judgment
Inactive
OK
The measurement is made after
inclination compensation.
Judgment and output are performed according to
the measurement result.
NG
The measurement is made
without performing inclination
compensation.
Judgment and output are performed according to
the measurement result.
Active
OK
Make the measurement after
inclination compensation.
Judgment and output are performed according to
the measurement result.
NG
The measurement is not made. Judgment and output will result in an error.
Scn 0
䂯䇭
Set
䂯
Image
Detect set
Meas set
Extra set
Meas mode
Output
Scn 0
䂯䇭
Set
䂯
OUT0:Height
OUT1:Step: 2 pts
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7:
operation.book Page 113 Monday, June 6, 2005 10:19 AM