Operation Manual
SECTION 6
Communication with External Devices
•
Different data is output depending on the setting in [Extra set/Hold&Logging].
Command executed correctly
: Number of measurement values
Measurement value
⋅
⋅
⋅
Measurement value
OK
At measurement error
: -999.999999
Other errors
: ER
No trigger occurred
: RST
LD-OFF
: LDOFF
If the mode is set to [Free]
: ER
If the mode is set to [Hold (External)] or [Hold (Self)], but
this command is executed during the trigger period: ER
The accumulated data is cleared under the following circumstances:
•
At startup
•
When clearing a scene
•
When switching a scene
•
When loading scene data
•
When loading system data
•
At initialization
•
When changing trigger settings
•
When the measurement period is changed
If the measurement is paused (e.g., when changing to the Set mode), logging data is maintained,
but the data accumulated by the external trigger and self trigger is cleared.
Setting
Output data
Free
ER
Hold (External)
Data accumulated in the period from the start of measurement to the
end of measurement
Hold (Self)
Logging
Logging data from the latest data and up to 3000 points in the past
Output
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter