OPERATION PANELS A-97
1.
The setting made for CAP parameter No. 142 is in effect only when the PANEL key-
switch is placed in positions other than the
(PANEL/EDIT) position.
2.
CAP parameters No. 140 and No. 142 are set to "0" at shipment.
3.
*1
Input operation for work offset data is invalidated only in automatic operation.
2.
Macro variable input interlock function
This function sets valid/invalid status of macro variable input operations in the MDI mode.
To validate or invalidate the input operation, set CAP parameters No. 141.
Contents of the interlock function is determined by the value set to the parameter as shown
below.
11
Input operation for tool geometry
offset data, tool wear offset data or
work offset data
*1
is invalid.
—
12
Input operation for work offset data
is invalid.
—
13 or
greater
Interlock function is invalid. (Input
operation for tool geometry offset
data, tool wear offset data and work
offset data is valid.)
—
Set Value
CAP Parameter
No. 141
0
Interlock function is invalid. (Input operation for macro variables is valid.)
1
Input operation for macro variables is invalid.
2
Input operation for macro variables is invalid in other than MDI mode.
Set Value
CAP Parameter
No. 140
No. 142
NOTE