F-58 PREPARATION BEFORE STARTING MASS PRODUCTION
14-4
Alarm Table
The pushing detection program is called by G38.
Since this program is written to ROM as a macro executor and not stored in the NC
memory, it is not possible to display or edit it.
It is not possible to change the G code.
No.
Message
Description
3001
B POSITION ERROR
The position obtained in the pushing
detection process is outside the
tolerance range.
3003
B, J AND V SPECIFIED
Two or more coordinate values are
specified.
3005
B POSITION NOT SPECIFIED
No target position is specified.
3007
SKIP NOT DETECTED
No B-axis current is detected during
axis feed up to the end position.
3008
SKIP ALREADY DETECTED
The specified level current is
detected at the start or just after the
start of Z-axis feed.
3009
RETURN AMOUNT IS NEGATIVE
The specified K value is not positive.
NOTE