OPERATION PANELS A-29
5-6-2
Optional Stop Switch [OSP]
When this switch is pressed, the indicator in the switch is
lit and the optional stop function becomes valid.
When this switch is pressed again, the indicator in the
switch goes off and the optional stop function becomes
invalid.
The valid and invalid status of the optional stop function changes simultaneously when
either of the optional stop switches
provided for turret 1 and turret 2 respectively is
pressed to change valid/invalid status.
<Optional stop function>
The optional stop function makes the M01 (optional stop) command written in a program valid.
This function is used to check the conditions of the cutting tool or to remove chips from the
machine during automatic operation and to check a program at each process of test cutting.
<When the optional stop function is valid>
In the optional stop mode, spindle rotation, coolant supply,
and axis feed stop after the execution of an M01 block.
The STATUS indicator
[M00/M01]
is lit.
To continue the interrupted operation, press the
(ST) switch.
Specify the M01 command in an independent block.
<When the optional stop mode is invalid>
Any M01 command is ignored and the program is executed continuously.
OSP
NOTE
X
Z
ERR
MRDY
TRCL
M00/M01
M02/M30
CHCL
STATUS
NOTE