DOOR INTERLOCK FUNCTION P-29
5-2-2
Releasing the Door Interlock Function (Automatic Door Type)
If it becomes necessary to carry out a work with the door opened after releasing the door interlock
function, follow the steps indicated below.
1)
Open the door by executing M85 (door open
command) or by pressing the AUTOMATIC DOOR
OPEN switch.
This door opening operation is not necessary if
the program has been ended after the execution
of M85.
2)
Place the DOOR INTERLOCK key-switch in the
RELEASE
position.
3)
Set the single block function ON for executing an
automatic operation to check the program or carry
out test cutting.
4)
Carry out necessary work.
If the DOOR INTERLOCK key-switch is placed in
the
NORMAL
position while carrying out operation
in the door interlock released state, all machine
operations stop.
5)
After completing the necessary work, set the door
interlock function ON.
a)
Place the DOOR INTERLOCK key-switch in
the
NORMAL
position.
b)
Return the single block function to invalid if the
operation has been executed with the single
block function set ON.
c)
Close the door by executing M86 (door close
command) or by pressing the AUTOMATIC
DOOR CLOSE switch.
The door is locked.
This door closing operation is not necessary if the
program begins with the door close command
(M86).
NOTE
DOOR INTERLOCK
NORMAL
RELEASE
NOTE
DOOR INTERLOCK
NORMAL
RELEASE
NOTE