OPERATION PANELS A-67
5-22
Steady Rest Switches (Steady Rest Specification)
The steady rest switches on the optional panel are used
to manually open and close the steady rest.
These switches are not operative when the
PANEL key-switch is placed in the
(OFF)
position.
Switch
Function
When this switch is pressed, the steady rest is placed in the manual mode.
The indicator in the switch is lit and manually opening/closing the steady rest is
possible.
Pressing the switch again causes the indicator to go off and the steady rest
manual mode is canceled.
When this switch is pressed in the seady rest manual mode, the steady rest is
opened and the indicator in the switch is lit.
When this switch is pressed in the steady rest manual mode, the steady rest is
closed and the indicator in the switch is lit or blinks.
The indicator blinks when the steady rest close is completed while the turret 2 X-
axis is at the zero point.
The indicator is lit when the steady rest close is completed while the turret 2 X-
axis is not at the zero point.
STEADY REST
1 OPEN
STEADY REST
MANUAL MODE
STEADY REST
1 CLOSE
NOTE
STEADY REST
MANUAL MODE
STEADY REST
1 OPEN
STEADY REST
1 CLOSE