MANUAL OPERATION B-43
8-2
Indexing the Turret After Setting the Target Station Number
The turret head is indexed in manual operation when mounting and removing tools, and to
measure tool compensation values.
1)
Place the DOOR INTERLOCK key-switch in the
NORMAL
position.
2)
Close the front door.
3)
Place the PANEL key-switch in one of the positions
indicated below.
(ON)
(PANEL/EDIT)
4)
Press the HEAD CHANGE switch
(head 1) or
(head 2) to select the required turret.
5)
Select any of the following modes with the MODE
selection switch.
(handle)
(jog)
(rapid traverse)
(zero return)
6)
Press the turret station setting switch
(increase) or
(decrease) to set the station
number to which indexing is required as the target
position.
The set station number will blink in the turret display
area.
DOOR INTERLOCK
NORMAL
RELEASE
ON
PANEL
/EDIT
OFF
PANEL
2
1
HEAD CHANGE
1
2
MODE
MEM
MDI
TAPE
EDIT
H
JOG
RPD
ZRN
TURRET