A-32 OPERATION PANELS
5-6-5
Machine Lock
The machine lock function is made valid or invalid on the
OPERATION PANEL screen, which is displayed by
pressing the function selection key
(SETTING).
To set the machine lock function valid or invalid for
turret 2, display the OPERATION PANEL screen
for turret 2 by pressing the HEAD CHANGE switch
(head 2).
<Machine lock function>
Manual axis movement operation and programmed axis movement commands are ignored. Only
position data is updated in response to the operation of an AXIS DIRECTION switch or the
execution of an axis movement command.
This function is used to check a program without axis movement operation.
<When the machine lock function is valid>
Manual axis movement operation and programmed axis movement commands are ignored.
The display of the current location changes as instructed.
<When the machine lock function is invalid>
Axis movement is carried out normally.
WARNING
Before switching the machine lock function from "valid" to "invalid", wait
until one program operation cycle has been completed. After switching
from "valid" to "invalid", always execute a zero return operation.
Switching between "valid" and "invalid" during program execution will
create a discrepancy between the position designated in the program and
the actual machine position, which could cause accidents involving
serious injuries or damage to the machine.