P-6 DOOR INTERLOCK FUNCTION
The functions of the controls are summarized below:
No.
Control
Function
1.
DOOR INTERLOCK
key-switch
<Part No.>
E61133
Makes the door interlock function valid, invalid (partly), and invalid.
<NORMAL>
When the DOOR INTERLOCK key-switch is placed in the
NORMAL
position, the door interlock function is made valid.
Keep the DOOR INTERLOCK key-switch in the
NORMAL
position.
<RELEASE>
When the DOOR INTERLOCK key-switch is placed in the
RELEASE
position, the door interlock function is partially
made invalid.
Under such condition, there are potential hazards in
operating the machine. To warn this state, the status
indicator
[INTERLOCK RELEASED]
blinks in red and the
electronic buzzer beeps.
Pay sufficient care if it becomes necessary to operate the
machine under such condition.
1.
Make sure that the status indicator
[INTERLOCK
RELEASED]
blinks in red and the electronic buzzer
beeps when the DOOR INTERLOCK key-switch is
placed in the
RELEASE
position.
2.
If the disconnection of the status indicator or
electronic buzzer circuit is detected, the door
interlock function cannot be released even if the
DOOR INTERLOCK key-switch is placed in the
RELEASE
position.
DOOR INTERLOCK
NORMAL
RELEASE
NOTE